A9.3
A9.3
It is often recommended that FS characteristics are to be found in the Rec.  Recommendation ITU-R F.758 -4 when FS frequency provides fixed service characteristics for sharing with aircraft-mounted FSS Earth stations in the band 27.5-29.5 GHz is considered. Note that Rec.  ITU-R F.758-4 has also been newly revised; the draft revision is currently in the final stage of being approved and publication of new version F.758-5 is expected soonband.. As specified in the Recommendation (Annex 2 of its , Section 4), the system parameters shown provided are not representative of any actual FS system, but represent an averaging or an expected range of values suitable for generic sharing/compatibility studies.

...

Antenna radiation patterns for FS-PP are usually assumed in sharing studies using the formulas in Recommendation ITU-R F.699 (when a single FS system is considered as victim/interferer) or Recommendation ITU-R F.1245 ( when averaging among a number of FS systems as victim/interferer). For P-MP it is recommended to use the Recommendation ITU-R F.1336.

 

Anchor
T069
T069
Table 69: Recommended FS characteristics for FS vs FSS studies


Parameter

FS1 (PP)

FS2 (PP)

FS3
(PP)

FS4
(P-MP)

FS5 (PP based on Rec. ITU-R 758-5)

FS6 (P-MP based on Rec. ITU-R 758-5)

Notes

RX antenna height

20 m

20m

20m

20m

Not specified, 20m is suggested

Not specified, 20m is suggested

 

RX antenna pattern

ITU-R
Rec.
F.1245

ITU-R
Rec.
F.1245

ITU-R
Rec.
F. 1245 

ITU-R
Rec. F.1336

ITU-R Rec.
F. 1245 

ITU-R
Rec.
F.1336

Source:
Rec F.758-5 (doc 5/BL/24)

Receiver noise figure, F

6 dB

6 dB

6 dB

6 dB

8 dB

8 dB

See note (1)[1]

RX frequency

28 GHz

28 GHz

28 GHz

28 GHz

24.25 – 29.50 GHz

24.25 – 29.50 GHz

 

RX elevation angle

10°

Not specified, 10° is suggested

Not specified, 0° is suggested

 

RX peak gain

45 dBi

43 dBi

35 dBi

18 dBi

 

6.5 dBi

 

See note (2)[2]

 