Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Anchor
A8.6
A8.6
To calculate the receiver attenuation in blocking response modes, the fundamental relationships between receiver sensitivity, wanted signal, unwanted signal (i.e. the interfering signal) and noise floor need to be established, based on the principle of measuring blocking as a level of adjacent interfering signal which results in reduction of output power from modulated useful signal by a certain limit.

...

  • The wanted signal (Generator A) is switched on, tuned at receiver frequency and its level is adjusted to the level of maximum useable sensitivety of the receiver, which corresponds to BER=10-2 at the receiver output. The level of wanted signal is then further increased by 3 dB;
  • The unwanted signal is added by switching on Generator B, with given frequency shift from receiver frequency, and its output level is first increased until a BER=10-1 or worse is obtained; then decreased again until the BER=10-2 is re-attained at the receiver output;
  • The corresponding level of unwanted signal is noted. The “blocking” ratio is then expressed as ratio, in dB, of the level of unwanted signal to the level of wanted signal;
  • Test is repeated for other frequency shifts Df.

Anchor
F394
F394
Figure 394: Blocking measurement arrangement (from ETSI EN 300 113)