- The wanted signal (Generator A) is switched on, tuned at receiver frequency and its level is adjusted to the level of maximum useable sensitivety of the receiver, which corresponds to BER=10-2 at the receiver output. The level of wanted signal is then further increased by 3 dB;
- The unwanted signal is added by switching on Generator B, with given frequency shift from receiver frequency, and its output level is first increased until a BER=10-1 or worse is obtained; then decreased again until the BER=10-2 is re-attained at the receiver output;
- The corresponding level of unwanted signal is noted. The “blocking” ratio is then expressed as ratio, in dB, of the level of unwanted signal to the level of wanted signal;
- Test is repeated for other frequency shifts Df.
Figure 396: Blocking measurement arrangement (from ETSI EN 300 113) Anchor F396 F396