Note: The calculation of the iRSS at each trial will be performed only if the location of the ILT satisfies the following condition .
Figure 133 129 presents how to set-up SEAMCAT (See also A13.2 for further details).
Figure 133129: Setting up the protection distance related to the simulation radius with 1 active interferer Anchor F133 F133
The simulation radius (see Figure 135131) may then be calculated by using the following formula:
Figure 134130: Calculated simulated radius Anchor F134 F134
Figure 135131: Calculation of the simulation radius and the iRSSunwanted using the protection distance (for 1 active interferer) Anchor F135 F135
If the distance between the VLR and the ILT is equal to the protection distance (0.5 km), then:
...
These results are in line with those depicted on Figure 135131. We can then increase the number of active transmitters to 10 as shown in Figure 136132.
Figure 136132: Setting up the protection distance related to the simulation radius with 10 active interferer Anchor F136 F136
The simulation radius may then be calculated by using the following formula (see Figure 137 133 for the result):
= 0.75 km
Figure 137133: Calculation of the Rsimu and the iRSSunwanted using the protection distance Anchor F137 F137
(for 10 active interferer)
...
-27 dBm < iRSSunwanted < -23.5 dBm (see Figure 137133)