If a minimum protection distance
d0 between between the
victim link receiver and interefering link transmitter ILT and the VLR is introduced
, then
Rsimu results ( based on the uniform density mode
) results in
the following equation:
Image Removed (Eq. 172)
...
Mathinline |
---|
body | ${{R}_{simu}}=\sqrt{\frac{{{n}^{active}}}{\pi \ \times \ dens_{ILT}^{active}}+d_{0}^{2}}$ |
---|
|
(Eq. 181)Each trial with
Mathinline |
---|
body | ${{d}_{ILT\to VLR}}<{{d}_{0}}$ |
---|
|
will be rejected and repeated for another trial
producing Image Removed producing Mathinline |
---|
body | ${{d}_{ILT\to VLR}}\ge {{d}_{0}}$ |
---|
|
.