Anchor | ||||
---|---|---|---|---|
|
- When delta ≥ 0, then the receiver is overloaded at that fi (i.e. the rest of the frequency do not matter);
- When delta < 0, then the receiver is not overloaded at fi.
If only one frequency is present, the iRSSsum_overloading is compared to the Oth(fi)and the difference will be stored for that event. If more than one frequency is present, the highest delta value will be indicated in the vector (i.e. irrespective of the frequency) such that
for each event j (where dRSS > sensitivity){
for Frequency = i to number of total frequencies{ delta_max(j) = max(delta(fi)); } (Eq. 67)
}
Figure 249: Overloading results folder Anchor F249 F249
The output delta overloading vector is of the dimension delta x number of events
Figure 250: Delta overloading result vector Anchor F250 F250