Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The first step is to estimate whether the transmitter and the receiver are located in the same building. This is done trough a statistic trial. Let us denote P the probability that the transmitter and the receiver are located in the same building. P is calculated according to the following scheme:

Anchor
T081T082T081
T082
Table 8182: Same-building probability

 

Dist. Range
(km)

Same Building
Probability

...

d<=0.02

...

P = 1

...

0.02

...

< d <= 0.05

...

P = (0.05-d)/0.03

0.05

...

< d

P = 0

 





 

Transmitter and Receiver in different buildings

When transmitter and receiver are located in different buildings, the calculation mode is similar to the indoor-outdoor propagation mode but with doubled additional values.

Median path loss

                            Image Removed                        

Mathinline
body$L_{indoor-indoor}^{hata}=L_{outdoor-outdoor}^{hata}+2\times {{L}_{ew}}$
  (Eq. 200209)

where 

...

                                

Mathinline
body$2\times {{L}_{ew}}=Loss_{Rx}^{wall}+Loss_{Tx}^{wall}$
  (Eq. 210)

Where  and are the attenuation due to external walls as defined in the Rx and Tx side respectively. 


Variation in path loss

                            (Eq. 202211)

Transmitter and Receiver in same building

...

The corresponding median path loss is given by the following formula :

Image Removed(Eq. 203)

with

...


Mathinline
body$L(indoor-indoor)=-27.6+20\log (\sqrt{{{({{h}_{2}}-{{h}_{1}})}^{2}}+{{(d)}^{2}}})+20\log (f)+fix\left( \frac{d}{{{d}_{room}}} \right){{L}_{wi}}+{{k}_{f}}^{\left[ \frac{{{k}_{f}}+2}{{{k}_{f}}+1}-b \right]}{{L}_{f}}$
 (Eq. 212)

with

      

Mathinline
body${{k}_{f}}=\left| floor\left( \frac{{{h}_{2}}}{{{h}_{floor}}} \right)-floor\left( \frac{{{h}_{1}}}{{{h}_{floor}}} \right) \right|$
 (Eq. 213)

where :

Lwi         : loss of wall (default 5 dB)

...

b           : empirical parameter (default 0.46)

droom           : size of the room (default 4 m)

hfloor             : height of each floor (default 3 m)

h2          : height of the transmitter receiver (m)

h1          : height  height of the receiver transmitter (m)