Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Anchor
4.2.3
4.2.3
This mode is identical to the “sensitivity” mode since the only difference is that the Blocking value (relative to the noise floor) is provided in dB. The software processes the information using exactly the same method to obtain the value of the receiver attenuation (see Figure 12see A8.7).

The function blockProtection Ratio(Df) that you entered represents the protection ratio, i.e. the ratio of maximum acceptable level of interfering signal to the wanted signal level, at a given frequency separation.

In this case SEAMCAT calculates the receiver attenuation aVLR(Df) to be applied to the interfering signal by using the following expression (see Figure 109105):

...

(Eq. 24)   

                       

Mathinline
bodyAttenuation (f) = blockProtection Ratio(f) (dB) + C/(N+I) (dB) + (N+I)/N (dB) – I/N (dB)

...

   

                       

Mathinline
bodyAttenuation (f ) = 40 + 16 + 3 - 0 = 59

...

dB

Mathinline
bodyiRSSblocking = Interfering Signal Level (f it ) = -54.5 - 59 = -113.5 dBm

...


     

                                            

 

Figure 109

Anchor
F105
F105
Figure 105: Mean iRSSblocking in case of Protection-ratio mode