Anchor | ||||
---|---|---|---|---|
|
In this case SEAMCAT calculates the receiver attenuation, Attenuation (Df), to be applied to the interfering signal by using the following expression:
Unit body Attenuation(
...
Df) =
...
blockMax Interf Signal (
...
Df) (dBm) -
...
sensVLR (dBm) + C/(N+I) (dB) – I/N (dB)
...
(Eq. 23)
where:
- Df = (fILT - fVLR) is the frequency separation;
- sensVLR is the sensitivity of the VLR (dBm) as defined in the simulation scenario.
To achieve a realistic value, you may define the sensitivity (sensVLR) as (see the figure below):
...
Sensitivity = -110 dBm + 16 = -94 dBm
Figure 107103: Setting up the sensitivity in SEAMCAT Anchor F107F103F107 F103
...
iRSSblocking = Interfering Signal Level (f it )= -54.5 - 150 = -204.5 dBm
This can be checked by running a simulation and displaying the iRSSblocking in case of Sensitivity mode calculated by SEAMCAT see Figure 108104.
Figure 108104: Mean iRSSblocking in case of Sensitivity mode Anchor F108 F108