Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Anchor
4.2.2
4.2.2
In this calculation mode the function blockMax Interf Signal (Df) that you entered represents the absolute power level (in dBm) of maximum interfering signal (maximum acceptable interfering power), which might be tolerated by the receiver at a given frequency separation (see Figure 12see A8.7).

In this case SEAMCAT calculates the receiver attenuation, Attenuation (Df), to be applied to the interfering signal by using the following expression:

                    

Unit
bodyAttenuation(

...

Df) =

...

blockMax Interf Signal (

...

Df) (dBm) -

...

sensVLR (dBm) + C/(N+I) (dB) – I/N (dB)

...

  (Eq. 23)

where:

  • Df = (fILT - fVLR) is the frequency separation;
  • sensVLR is the sensitivity of the VLR (dBm) as defined in the simulation scenario.

 


To achieve a realistic value, you may define the sensitivity (sensVLR) as (see the figure below):

...

Sensitivity = -110 dBm + 16 = -94 dBm

Image Removed Image Added

Anchor
F107F103F107
F103
 Figure 107103: Setting up the sensitivity in SEAMCAT

...

iRSSblocking = Interfering Signal Level (f it )= -54.5 - 150 = -204.5 dBm        

 


This can be checked by running a simulation and displaying the iRSSblocking in case of Sensitivity mode calculated by SEAMCAT see Figure 108104.

  

Anchor
F108
F108
Figure 108104: Mean iRSSblocking in case of Sensitivity mode