Unit
bodyAttenuation(fDf) = blockMax Interf Signal (fDf) (dBm) - sensVLR (dBm) + C/(N+I) (dB) – I/N (dB)
  (Eq. 23)

...

Sensitivity = -110 dBm + 16 = -94 dBm

Image Removed Image Added

Anchor
F107F103F107
F103
 Figure 103: Setting up the sensitivity in SEAMCAT

...

This can be checked by running a simulation and displaying the iRSSblocking in case of Sensitivity mode calculated by SEAMCAT see Figure 104.

  

Anchor
F108
F108
Figure 104: Mean iRSSblocking in case of Sensitivity mode