Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

The following graphics presents the input paremeters to activate when the overloading mechanism is to be simulated.

Figure 111: Activation of the overloading feature in SEAMCAT

 

The overloading mask is expressed in power (dBm) versus frequency offset (MHz) and is defined as a function in SEAMCAT. 

 

Figure 112: Setting of the overloading mask in SEAMCAT

The filtering of the receiver is expressed in power (dB) versus frequency offset (MHz) and is defined as a function in SEAMCAT (see Figure 113). It is set by default to a constant value of zero.

Note that if the blocking attenuation mode in user-defined and the overloading feature have been selected, then a consistency check will remind you that the actual blocking response and the receiver filter are the same element and they should not be accounted twice.

Figure 113: example of filling the Rx filter function

When a simulation is run the following results are extractable (see Section 12.3.4 for further details)

As an example, this means that for the following overloading mask presented in Figure 3 with a victim frequency of 908 MHz and an interfering frequency of 900 MHz, the delta frequency (i.e. frequency offset) is -8 MHz with an overloading treshold of -8.5 dB and a Rx filter value of 9 dB. This can be found from the log file as shown below in Figure 114.

Figure 114: Output from logfile


  • No labels