Based on the definition and measurement procedure of blocking, it is possible to obtain the receiver attenuation parameter aVLR(Df) from the following fundamental relationships between wanted and unwanted signals, receiver sensitivity and noise, as observed when blocking event is triggered:

Figure 395: Relationship between signal levels when blocking occurs
(Protection Ratio and Sensitivity modes)


Note: the coloured arrows show the relationship of the input parameters used for the calculation of the resulting blocking response (aVLR(∆f)) and described in the sections above.

Examples:

VLR      noise floor:                   -114 dBm

            sensitivity:                    -98 dBm

            C/(N+I):                         16 dB

            I/N:                               -6 dB

            (N+I)/N                          1 dB

 

a)         blocking mode "Sensitivity"
            limit:                            -45 dBm

 

 

b)         blocking mode "Protection ratio"           

            limit:                            52 dB

 

                                               

 

75 dB