When a BS is selected, the following information is shown (Figure 440 and Figure 441 for UL and Figure 442 for DL).

 

Figure 440: BS selected

 

Figure 441: Downlink BS selected

Figure 442: Uplink BS selected

 

Table 76: Parameters of selected base-station

 

Name

Description

Link direction

Cell ID

ID of selected base-station

General

Transmit power

Transmit power of the BS

Downlink

Total interference

Sum of internal and external interference at the BS

Uplink

Number of served users

Sum of voice active and voice inactive UEs

General

Antenna Height

Value from the input distribution

General

Number of dropped users

UEs dropped from the base-station

General

Outage percentage

Fraction of connected UEs that were dropped

Downlink

Noise rise over Noise Floor

The noise rise experienced at the selected BS

Uplink

Position

(X,Y) in km

General

Pilot channel Power

Power for the pilot channel power as deducted from the pilot channel fraction and the maximum transmit power

Downlink

Overhead channel power

Power for the overhead channel as deducted from the overhead channel fraction and the maximum transmit power

Downlink

Number of active users

Number of connected UEs who has this BS as their primary link.

Downlink

Intersystem interference

Sum of interference from all UE’s not connected to this BS

Uplink

External interference, Unwanted

Unwanted part of external interference

Uplink

External interference, Selectivity

Selectivity part of external interference

Uplink

Active connections

Number users connected to this BS (primary and secondary links)

General

Is Reference cell

When TRUE, then it is the reference cell

General

 

 

 