Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Anchor
6.3
6.3
For the sensing feature to be activated, both the victim and interferer transmitters have to have the “interferer is CR” selected (Figure 158). This will activate the spectrum sensing algorithm (see ANNEX 16:) and will allow you to set the transmitting characteristic of the victim link transmitter, i.e. the energy that the cognitive radio spectrum sensing device is to sense. You will be able to set the emission mask and the emission floor. 

 Image Added

Anchor
F158
F158
Figure 158: Selection of the CR algorithm

 

Anchor
T020
T020
Table 20: Victim Link transmitter


Description

Symbol

Type

Unit

Comments

Interferer is CR


switch


When the CR button is checked then it allows to set the emission characteristics of the VLT (used for the sRSS calculation only)

Emission mask:

Unwanted signal level (VLT)



Function (X,Y) (MHz)

dBm/reference bandw. (MHz)

Define the mask of the transmitter, in the emission bandwidth and out of the emission bandwidth.

Negative values in the relative mask should be chosen in a way that the integration over the emission bandwidth results in the total emitted power. If constant mask, there is no emission outside of the bandwidth.

Unwanted emissions floor: Noise floor signal level


Function (X,Y) (MHz)

dBm/

reference bandw. (MHz)

Define the minimum strength of the unwanted emissions.

So the unwanted emissions equal to Max(Pwt + Unwanted emission, Unwanted emissions floor)


 Note that the settings of the emissions mask and the emission floor is the same as for the interfering link (i.e. same units).

 

 Image Added 

Image Added

Anchor
F159
F159
Figure 159: Activate the CR in the VLT (Victim Link) to consider its emission characteristics
(i.e. used in the sRSS calculation)