Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Anchor
8.3.1
8.3.1


Anchor
T027
T027
Table 27: CDMA general settings input parameters


Description

Symbol

Type

Unit

Comments

Receiver Noise Figure

 


Scalar

S

dB

Equipment-specific noise figure of receiver. It is used to calculate the noise floor. See Section‎1.2.2

Handover margin

 


Scalar

S

dB

Specifies the maximum difference between the links in users active list. The actual active-list selection is based on pathloss calculations.

Call drop threshold

 

S


Scalar

dB

Threshold to determine call drops. It is used by the power control to determine if a user should be dropped when not meeting exact target requirement.

Voice bit rate

 

SS


Scalar

kbps

it is used to calculate the processing gain. See Section ‎8.7.1.

processingGain = 10*log10(systemBandwidth (MHz) / voiceBitRate (kbps) * 1000);

Reference bandwith

 


Scalar

MHz

Bandwidth of the system. It is the same for either UL or DL.

Voice activity factor

-

-

-

It is set to 1, i.e. 100% (all voice users that are generated are active). It is not editable.

Minimum Coupling Loss

 

S


Scalar

dB

The minimum path loss. It is used in the calculation of the effective path loss depicted in section ‎7.6.1

Link Level Data

 

F

 


Function (X,Y)


Drop-down selection of Link level data look-up functions from Library. It is user's responsibility to choose an appropriate set of data. See Section ‎8.5 for further details

 

...