Anchor | ||||
---|---|---|---|---|
|
(Eq. 169
Mathinline | ||
---|---|---|
|
densitactive isthe density of active transmitters and is defined as follows:
...
(Eq. 170
Mathinline | ||
---|---|---|
|
where:
- nactive - number of active transmitters set in the scenario for IT-VR path (note htat that nactive should be sufficiently large so that the (n+1)th interferer would contribute with a negligible additional interfering power);
- densit - density of transmitters, 1/km2, user-defined parameter in the table Interferers density of ILT-VLR path;
- Pit - probability of transmission, user-defined parameter;
- activityit(time) - user-defined temporal activity function (i.e. look-up table). The time value used for calculation is specified in the parameter time (see below).
- time - parameter defining which of the values in the above activity function should be used in calculations (e.g. if the activity(time) function contains three pairs: (1;0.5), (2;0.7), (3; 0.9) and the time parameter is set to 2, then the activity(time) function will return a value 0.7).
In case a fixed simulation radius with a defined density of active users is provided, the number the nactive users can be evaluated by using the following equation, which is derived from the above equation.
Mathinline | ||
---|---|---|
|
...
|
...
When setting up your simulation, if the relevant input parameter is the simulation radius, it is recommended to use the mode “None” instead of the “Uniform density” mode. In that case, the activity of the transmitter may be simulated using e.g. the parameter duty cycle, which defines a distribution of the transmit power.
...