This panel is available only if OFDMA UL is selected and is the input parameters to the UL OFDMA power control described in Section ‎9.10.

Table 35: OFDMA UL power control input parameters

Description

Symbol

Type

Unit

Comments

Maximum allowed transmit power of mobile

 

Scalar

dBm

Transmit power of the UE

Minimum transmit power of mobile

 

Scalar

dBm

Minimum transmit power used in the power control.

Power Scaling Threshold

 

Scalar

 

Used in the calculation of the path loss limit for the power control. It is a limit threshold compared to the value of the CDF used in the power control. With this power control scheme, the 1-“ Power Scaling Threshold” percent of UEs will transmit at Pmax, i.e. are not power controlled

Balancing factor (0<γ<1)

 

Scalar

 

Balancing factor for UEs with bad channel and UEs with good channel.

Estimate coupling loss percentile

CLx-ile

calculator

 

This calculator allows you to estimate the coupling loss percentile used in the simulation

 