Using the Free space equation, you can easily derive the power received by the Victim link receiver dRSS:

dRSS = Pe + Ge + Gr - L                                                                   (Eq. 17)

dRSS = 30 + 9 + 9 - (32.5 + 10 log(8) + 20 log(1000))                          

dRSS = -53.5 dBm                                                                            

 

Keep this calculation in mind, as we will compare it with what SEAMCAT calculates in the following sections