Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

A8.2.1   Case 1: No overlap

Figure 384:  iRSS_blocking case 1: no overlap

 

 

 

where:

lower:   offset - BWILT/2 – emission mask asymmetry[1]

upper:   lower + BWILT

dF:       step size, e.g. min{0.1;( BWILT)/20}

A8.2.2   Case 2: Partial overlap with fILT > fVLR

Figure 385: iRSS_blocking case 2: partial overlap with fILT > fVLR

 

Note: the blue coloured range is covered by the iRSS_unwanted calculation and therefore not taken into account in the iRSS_blocking calculation.

 

 

where:

 

lower:   BWVLR/2

upper:   offset + BWILT/2 – emission mask asymmetry

dF:       step size, e.g. min{0.1;( BWILT)/20}

 

A8.2.3    Case 3: Partial overlap with fILT < fVLR

Figure 386: iRSS_blocking case 3: partial overlap with fILT < fVLR

Note: the blue coloured range is covered by the iRSS_unwanted calculation and therefore not taken into account in the iRSS_blocking calculation.

 

 

 

where:

 

upper:   - BWVLR/2

lower:   – offset - BWILT/2 – emission mask asymmetry

dF:       step size, e.g. min{0.1;( BWILT)/20}

A8.2.4    Case 4: Total overlap with BWVLR < BWILT

Figure 387: iRSS_blocking case 4: Total overlap with BWVLR < BWILT

Note: the blue coloured range is covered by the iRSS_unwanted calculation and therefore not taken into account in the iRSS_blocking calculation.

 

 

 

where:

 

lower:   offset - BWILT/2 – emission mask asymmetry

upper:   lower + BWILT

dF:       step size, e.g. min{0.1;BWVLR/5}  1)

            excluding the range fVLR ± BWVLR/2

 

Note that at least 3 samples are required for the range fVLR ± BWVLR.

 

 

A8.2.5    Case 5: total overlap with BWVLR > BWILT

Figure 388: iRSS_blocking case 5: total overlap with BWVLR > BWILT

 

In this case, there is no blocking as the interference is completely covered by the unwanted calculation. The blocking attenuation is therefore set to 1000 dB.

A8.2.6    Implementation of the integral for iRSS_blocking

The integral requires positive values of the blocking mask, i.e. the blocking mode has to be considered first.

 

 

where: n = range/dF  and range = upper-lower

The parameter maskValue(f) corresponds to the following equations (see section 1.4.6).

           

  • For generic systems in user-defined mode, it corresponds to the mask specified in the receiver settings;

maskValue(f) = BlockUD (dB).

 

  • For generic systems defined with blocking modes different to user-defined (i.e. sensitivity and protection ratio);

 

    • Protection Ratio (dB):

 

maskValue(f) = BlockPR (dB) + C/(N+I) (dB) + (N+I)/N (dB) - I/N (dB) 

 

    • Sensitivity Mode (dBm):

 

maskValue(f)  = BlockSens (dBm) – SensitivityVLR (dBm) + C/(N+I) (dB) – I/N (dB)   

 

  • For cellular systems:
    • If the mask is defined in positive values (ACS), then maskValue(f) corresponds to the mask specified in the receiver settings;     
    • If the mask is defined in negative values, then  maskValue(f) corresponds to the calculated positive mask using the input parameters Standard Desensitization and I/N_target (see section A8.2.8).

A8.2.7   Considerations on the bandwidths used in the integral

Calculation of BW for GENERIC systems

The algorithm is based on the mask entries and takes the values as relative to the carrier (dBc) at the zero offset.

It consists of two loops, one for the upper part of the mask, the second for the lower part.

The loops stop if the relative power of the actual offset is less than the limit .

The lower and upper bound are saved as they are required by the calculation algorithm so that the blocking average takes account of symmetrical emission masks.


Calculation of BW for OFDMA

For a Base Station: the total number of resource blocks (max. RBs per BS) multiplied by the bandwidth of one resource block.

For a User Equipment: the bandwidth is: the number of RBs per MS (UE) multiplied by the bandwidth or one resource block.

 

Calculation of BW for CDMA

The algorithm uses the reference bandwidth of the system, which is the same for either BS or UE (user defined in CDMA general settings). .


A8.2.8    Conversion of negative blocking mask values in cellular receivers (OFDMA and CDMA)

In case of receivers of cellular systems (OFDMA and CDMA), if the mask has negative values, it needs to be converted  using the following input parameters in the receiver settings:

  • Standard desensitisation (for which the blocking mask values where derived);
  • Target I/N  (which depends on the scenario considered and can be extracted from the CEPT/ECC or ITU-R deliverables ).

 

If the mask is entered as positive values then these parameters are not used.

 

Figure 389: Input parameters for cellular receivers blocking masks

 

Default values of standard desensitisation and Target I/N are specified in the table below.

 

Table 67: Default values of standard desensitisation and Target I/N

 

Standard Desensitization (dB)

Target I/N (dB)

OFDMA UL

+6

-6

OFDMA DL

+6

-6

CDMA UL

+6

-6

CDMA DL

+3

-6

 

The algorithm to convert negative blocking mask values is as follows:

 

Blocking Response = IOOB_target – Noise floor – I/Ntarget

 

where:

 

  • I/Ntarget is always understood as ‘target I/N of the victim’, which is calculated for D_target (target desensitisation)
  • Noise floor = 10*log(kTB) + F.
  • K= Boltzmann Constant
  • T = Noise temperature (Kelvin)
  • B = Receiver bandwidth in MHz
  • F = Noise Figure (dB)
  • IOOB_target is calculated as follows :

 

IOOB-TARGET = IOOB-STANDARD – DSTANDARD + DTARGET

 

where:

 

  • IOOB-STANDARD = is the original blocking mask;
  • DSTANDARD = is the standard desensitisation for which the blocking mask values (IOOB-STANDARD) were derived. It is an input of cellular receiver settings (see Figure 389).
  • DTARGET = 10*log10(10^(I/N_target/10)+1) ; where I/N_target is an input of cellular receiver settings.

 

Finally we obtain:

 

Blocking Response = IOOB-TARGET – Noise floor– I/Ntarget, which means:

 Blocking Response = IOOB-STANDARD – DSTANDARD + DTARGET – kTBF – I/Ntarget          



[1] requires the bounds of  the bandwidth

  • No labels