Using the Free space equation, the power received by the Victim link receiver (dRSS) can be easily derived:

dRSS = Pe + Ge + Gr - L                                                                   (Eq. 17)

dRSS = 30 + 9 + 9 - (32.5 + 10 log(8) + 20 log(1000))                          

dRSS = -53.5 dBm                                                                            

 

Keep this calculation in mind, as it will be compared with what SEAMCAT calculates in the following sections.